Please use this identifier to cite or link to this item: http://www.ptolomeo.unam.mx:8080/xmlui/handle/132.248.52.100/14939
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRivera Mendoza, Orlando R.-
dc.date.accessioned2018-03-21T02:31:50Z-
dc.date.available2018-03-21T02:31:50Z-
dc.date.issued2007-04-
dc.identifier.urihttp://132.248.52.100:8080/xmlui/handle/132.248.52.100/14939-
dc.description.abstractSTAMPING DIRECTLY ON THE VESSEL WHEN CODE STAMPING IS APPLIED DIRECTLY ON THE VESSEL, STAMPING MUST: -DONE USING LETTERS AND FIGURES AT LEAST 5/16” HIGH. -BE ARRANGED PER FIGURE UG-118 WHERE SPACE PERMITS.es_ES
dc.description.sponsorshipDECDFIes_ES
dc.language.isoenes_ES
dc.subjectRecipientes a presiónes_ES
dc.subjectStamping, vessel, nameplate, mode of inspection, type of construction, postweld heat treatment, removable parts, UG-90 (c) (2), inspection agreement, quality control system, renewal of code symbol stamps, manufacturer´s data reportses_ES
dc.titleDiplomado en Recipientes a Presión: Módulo III (Marcado y Certificación de Recipientes a Presión Conforme a la Sección VIII, Div, 1 del Código ASME)es_ES
dc.typeApunteses_ES
dc.director.trabajoescritoRivera Mendoza, Orlando R.-
dc.carrera.ingenieriaIngeniería mecánicaes_ES
Appears in Collections:Colección Mecánica, Mecatrónica y Automotriz

Files in This Item:
File Description SizeFormat 
decd_5080.pdf726.02 kBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.